Garbage Grab Crane Troubleshooting table

Oct 27, 2017

Garbage Grab Crane Troubleshooting table

 

Trouble phenomenon

Trouble Reason

Maintenance method

1Operating   circuit

When the power supply cabinet is open QF0, the fuse is   fused

There is a short circuit   in the operating circuit

Check the ground   insulation to eliminate grounding faults

Power contactor KM0 cannot   be connected

1)          Line no voltage QF0

2)          The supply knob is unclosed

3)          The stop switch is not lifted

4)          The control handle is not zero position

5)          The motor protector contacts the point of disconnect

6)          3  4FU circuit   break

7)          Zero protection or threshold contact circuit breaker

8)          KM0 coil breaker

1Use a watch to   check for voltage

2-8Check each   component to find the breaking point

9Check the KM0   coil or replace the coil

After the controller closes, the motor protector moves

1)          Setting value is small

2)          There is a grounding fault in the stator circuit

3)          Overpressure or underpressure

4)          Loss of phase

5)          The mechanical part has a card death

1)          Standard adjustment

2)          Use a megohm to find out where the insulation is   damaged

3)          Adjust voltage

4)          checked the line

5)          Find the dead part of the card

抓斗控制电源送不上The grab control power cannot   be delivered

1)          The control handle is not zero

2)          Transformer KB1 does not output

3)          The power module U01 is not exported

4)          The motor protector contacts the point of disconnect

5)          The intermediate relay K000 is damaged

6)          The intermediate relay K000 is damaged

 

 

1)          Put the handle to zero

2)          Repair KB1 and related lines

3)          Troubleshooting U01 and related lines

4)          Check the components to find the breaking point

5)          K000 Replace the   intermediate relay K000

Trouble phenomenon

Trouble Reason

Maintenance method

The operation controller, the motor can only turn in one   direction

1) The controller   is single-phase failure

2) When repairing, connect   the wrong line

1)          Check controller

2)          Find fault and recover

The lifting wire rope does not rise

1)          The grab control handle is damaged

2)          Lift motor protector action

3)          No movement or signal of contact K11 or K21 is   transmitted to PLC

4)          No movement or signal of the rotor resistance   switching contactor K431 is not transmitted to PLC

5)          Upper mechanical limit

6)          Upper electrical limit

7)          The intermediate relay K000 is damaged

8)          Lift motor brake failure

1)          Check control handle

2)          Inspect the lifting motor protector

 

3)          Maintenance contactor K11 or K21

4)          K431 Maintenance   contactor K431

5)          Adjust of mechanical limit

6)          Adjust electrical limit

7)          K000 Replace the   intermediate relay K000

8)          Check brake

The lifting wire rope does not drop

1)          The grab control handle is damaged

2)  Lift motor protector action

3) No movement or signal   of contact K11 or K21 is transmitted to PLC

4) No movement or signal   of the rotor resistance switching contactor K431 is not transmitted to PLC

5) The intermediate relay   K000 is damaged

6) Lift motor brake   failure

1) Check control handle

2) Inspect the lifting   motor protector

3) Maintenance contactor   K11 or K21

4) Maintenance contactor   K431

5) Replace the   intermediate relay K000

6) Check brake

Not action when open and close steel wire rope

1) The grab control handle   is damaged

2)  Lift motor protector action

3) No movement or signal   of contact K11 or K21 is transmitted to PLC

 

 

1)          Check control handle

2)          Check the closed motor protector

3)          Maintenance contactor K11 or K21

4)          Replace the intermediate relay K000

5)          Check brake

Trouble phenomenon

Trouble Reason

Maintenance method

2Motor

motor overheating

1)          The current rate exceeds the set value

2)          The driven mechanical failure (bad lubrication and   so on)

3)          power is too low in voltage

1)          Lighten Load

2)          Check the free rotation of the machine

3)          Reduce load or raise voltage

Operate the controller,   the motor does not turn

1)          There is no electricity in the line

2)          Default Phase

3)          Poor contact with controller contacts

4)          Brush and slip line contact bad or broken

5)          The rotor is open

1)          Check the presence or absence of voltage with the   table

2)          Check whether the phase is missing

3)          Check the contact information of the controller with   the table

4)          Observe and adjust the contact condition of brush   and slip line

5)          Check whether the rotor is broken or brush contact   is not good

Low output power and slow speed of motor

1)          The brake is not released

2)          The starting resistance in the rotor or stator   circuit is not safely removed

3)          mechanical jam phenomenon

4)          grid voltage drop

1)          Check and adjust the brake

2)          Check the resistive resistor circuit components so   that the contactor is operating normally

3)          Eliminate mechanical failure

4)          Eliminate the voltage drop cause or adjust the load

The motor has an abnormal   sound during operation

1)          bearing lack of oil or ball singeing

2)          rotor wiping the core

3)          Slot expansion

4)          Have sundries inside (iron filings)

1)          Fill or replace the bearing

2)          Replace the bearing or repair the bearing or process   rotor

3)          Change

4)          Clean

3Others

Step foot switch to grab   and do not move

1)          Foot switch damage

2)          K014损坏Intermediate relay K014   damage

1)          Change foot switch

2)          K014 Replace the   intermediate relay K014

 